Loading...
HomeMy WebLinkAbout13.A.1. Street Lighting on CSAH 101 from 1st Ave. to Fillmore St. and to Mill Pond BridgeCITY OF SHAKOPEE Memorandum TO: Mayor & City Council Mark McNeill, City Administrator FROM: Bruce Loney, Public Works Director SUBJECT: Discussion of Street Lighting on CSAH 101, from 1 Avenue to Fillmore Street and to Mill Pond Bridge DATE: December 20, 2010 INTRODUCTION: BACKGROUND: Staff would like Council direction on which fixture style they would prefer. This agenda item is to update the Council of lighting design changes and to clarify the extent of the lighting improvements. On the October 11, 2010 City Council meeting, the Council voted to proceed with Option 2 lighting design and extend to Huber Park. Option 2 lighting included light emitting diodes (LED) fixtures and a 27 -foot high decorative pole. Since this meeting, the County's consultant has prepare detailed drawings and cost estimate for this lighting. Attached to this memo are the drawings for the lighting, from Fillmore Street to the Mill pond bridge. The cost of the system that Mn/DOT will pay to meet their criteria which, is a high pressure sodium (HPS) and 30 -foot poles is $365,000.00. The lighting system with 27 -feet high decorative poles and LED fixtures is $480,000.00. In meeting with Shakopee Public Utilities Commission (SPUC) staff and review of the payback for LED fixtures versus HPS fixtures, the extra cost cannot be justified at the current estimates. The City does receive power donations from SPUC on these lights so it is difficult for staff to recommend paying additional cost with no payback to the City. In redesigning the system, the lights poles need to be 30 -feet in height for 250 watt HPS and this cost is estimated at $385,000.00. The light fixture design can be a shoebox design or standard cobra head designs (drawings attached). Also, staff would suggest that we bid an alternative design for 27 -feet high poles and LED fixtures, to determine the actual cost differential and then do a cost analysis with SPUC staff to see if LED's would be cost effective or not. Staff would like Council concurrence on an alternative bid for lighting. In addition, staff has included a lighting design from 1S Avenue to Fillmore Street, which would be five (5) additional lights and 100% of the City's cost. Staff believes this is the intent of the October 11, 2010 meeting and does go to the 1 signal and entrance to Huber Park. Cost of a new lighting system for (5) LED's is $69,000.00 and for (5) HPS's is $61,000.00. Staff recommends continuing the lighting system along C.R. 101 to 1 Avenue and it is actually less expensive than replacing the existing (9) lights with a 17 -foot high pole. The cost of replacing the existing (9) lights is estimated at $82,000.00. Staff would like to verify the intent of Council motion on October 11, 2010 and to continue the lighting pattern on C.R. 101. ALTERNATIVES: 1. Approve a motion to approve the lighting layout using 30 -foot decorative poles and high pressure sodium shoebox light fixtures, from Fillmore Street to the Mill Pond bridge. 2. Approve a motion to approve the lighting layout using 30 -foot decorative poles & high pressure sodium cobra head fixtures, from Fillmore Street to the Mill Pond bridge. 3. Approve the lighting layout on CR. 101, from 1 Avenue to Fillmore Street, using 30- foot high decorative poles with HPS fixtures similar to C.R. 101 from Fillmore Street to the Mill pond bridge. 4. Do not approve replacement of lights on C.R. 101, from 1 Avenue to Fillmore Street. 5. Approve a motion to bid 27 -foot high decorative poles and LED fixtures as an alternate for 1 Avenue to the Mill Pond bridge. 6. Do not approve a motion to bid a LED lighting system alternate. 7. Table for additional information. RECOMMENDATION: Staff recommends Alternative No.'s 1, 3 and 5. ACTION REQUESTED: 1. Approve a motion to approve the lighting layout using 30 -foot decorative poles and high pressure sodium shoebox light fixtures, from Fillmore Street to the Mill Pond bridge. 2. Approve the lighting layout on CR. 101, from 1 Avenue to Fillmore Street, using 30- foot high decorative poles with HPS fixtures similar to C.R. 101 from Fillmore Street to the Mill pond bridge. 3. Approve a motion to bid 27 -foot high decorative poles and LED fixtures as an alternate for 1 Avenue to the Mill Pond bridge. H:\2009 ENGINEERING PROJECTS \CR101 RECONSTRUCTION \WORD\LIGHTING - DESIGN.DOCX ruce Loney, P. Public Works Director 202.5 SEAM 10 0 wsl.ax Bzs7 00OTT Bo• CARBON STEEL - BASE RATE 210 5 E STE2 2 FR@1 MASi� -SEAN wELD- -POLE N -BASE DETAIL- 5. FINISH - BETA Li0N11N6 COLORFAST DELTA GUARD BRONZE 0 OASTARO TARE. PRE SHAFT ARO H -MSE SHIRT Tw STAINLESS TCCL AS SOA00 PSI NiTx v1[t OTAF[R x1L,v1a¢ LABASE 34000 PSI BASE YIELD PER S111 1 GRBM STEEL A R0 2171 un1Ea1AL- HIM SIREwTH L0V Al1D0 0 10EL 42.000 PSI 010 11[10 PER 0310 0500 0a B DO NOi GROUT BETWEEN TIE BASE RATE AND THROUGH T E P E MUST 7O BE PREVENT MOISTURE FLOW HE POLE. NOM MAL -TYPE 2 DETAIL- DECORATIVE DNB w61.14 NOMINAL T WISH. 1 I 79546 LMINAIRE OCTAIL- 00x107 L WA.. Inc. 0010.00R1m.. 0..47404 ERTIFV Tn A11360B REPoai R.5 PREPNNp SSl0xu [wIHfR iIE TT.1[ OE u1Nis01w BRYAN T. NCUETH o. 43354 CANA oacolo 810 B O L T O N $ N 1 N K , INC. CONSULTING ENGINEERS & SURVEYORS AHIATO. w1 FADUIMT 1a SLEEPY Ey . YR 0111000. LL Np BUD.VE. 4N 0.1.4A. uN RAM EY. MN APLEWOOD. IAN AWES.IA S.A.P. 70- 701-07 C.T.B.. C.P. 101 -07 C.S.A.H. 1O1 RECONSTRUCTION • LIGHTING DETAILS SHEET 137 162 TO A0010 INTERFERENCE WITH LIGHT BASE. PLACE ALL CONDUIT INSIDE AN T DIA. CIRCLE 4 MAX.— I I/4' NOM. DIA. BD TOM WIT P . V .E. FL SH WITH CONDUIT CONCRETE l< ELEVATION 2' 0' DIA. PO4 P.V.C. CONDUIT WITH 90 ELBOW PLACED 12' BELOW TOP GROUND OF FOUNDATION FOR GROUND HIRE WHEN GROUND ROD IS REQUIRED I I/O ' 01A. P.V.C. CONDUIT WITH 90 ELBOW. I CONDUIT REQUIRED FOR EACH CABLE ENTERING TIE LIGHT BASE. PROVIDE I ADDITIONAL CONDUIT FOR FUTURE EXPANSION ICAP BOTH ENOSI SEE ANCHOR ROD OET All LIGHT BASE DESIGN E MODIFIED 2 -N0.13 BARS 6' 0' LONG IOTA!, BARS S /8'DIA. ICOPFER COATEDI GROUND ROD WITH CLAW AND NO.6 BARE COPPER WIFE. SEE PLAN FOR GROUND ROD LOCATIONS.O 3' MIN. ANCHOR ROD PLACEMENT NOTES: CONOIEIE SHALL BE MIX NO. 3043. 3 HEAVY HEW NUTS PER ROO 0 P DIA. 2 -I/ ANCHOR ROD DETAIL 4 REOUIREO pt FOLPOATIOMS MAT BE CONSTRUCTED IN AUGURED HOLES (BLESS THE NATURAL SOILS WILL 101 STAND OPEN. IN WHIOI CASE FORMING WILL BE REQUIRED. P.V.C, CONDUIT PER SPEC. 3803 SHALL BE PROJECTED 1• ABOVE THE FOUNDATION BEFORE THE MORTAR IS PLACED AND SHALL BE THE SIZE AND NUMBER SHOWN IN TIE PLAN. A TEMPLATE SHALL BE PROVIDED FOR ANCHOR ROO PLACEMENT AND SHALL BE LEFT IN PLACE UNTIL THE CONCRETE HAS SET. WHEN ROCK IS ENCOUNTERED. SEE PLAN DETAILS. AN ALTERNATE PRECAST RASE MAY BE USED ROTH THE ENGINEERS APPROVAL. IQ THE DEPTH OF THE FOUNDATION MAT BE CHANGED IN THE PLANS OR SPECIAL PROVISIONS. O ANCHOR ROOS PER SPEC. 3385. TYPE B OR C SHALL BE RACED Al RIGHT ANGLES TO TIE DIRECT/00 OF THE MAS ARM. GALVANIZE 111E TOP I FT. OF THE ANCHOR ROD AND NUTS PER SPEC. 3392. 0 WRAP THREADS of ANCHOODS BELCH BOTTOM MIT ROTH ] LAYERS OF PLAST IC R ELECTRICAL TAPE. O PLACE GROUND ROO 3' TO 6' DEEP AND WITHIN I' OF EASE. CIWMF«, A M.N, IK in. MRI.nI• R.AW....A ! (ti-J llt� lotarLv I R BT CERTIFY IHAI THIS AN. CI ICA, ION OR REPORT •• • OT NE DR LACER PROFESSIONAL ENGINEER LNOCR INC LA Of THEE STATE Of MINNESO BRYAN . NEMETH M o 3354 Iota DAN M JBN CMCMO BTN � l B O L T O N 8- ME Y IN C. / I ll ll CONSULTING ENGINEERS & SURVEYORS NKATO. MN FAIRMONT. MN SLEEPY EYE. MN N R BIRNSVILLE. IN CHASKA, MN RAMSEY, IN MAPLEWOOD. MN AMES. IA CI M:111 __ � MME NEM - - _ S.A.P. 70- 701 -07 C.T.B., C.P. 101 -07 C.S.A.H. 101 RECONSTRUCTION LIGHTING DETAILS 138 OF 162 LIGHTING STANDARDS AND BASES NO. STATION OFFSET LOCATION TYPE IA.2A 110 +65.77 42.96 RT RET. WALL 2 3A 112 +75.43 38.49 RT SIDEWALK 1 4A 114 +55.43 38.49 RT SIDEWALK I 5A 116 *40.65 38.50 RT SIDEWALK I 6A.7A 118 +20.65 38.50 NT SIDEWALK 2 594 604 111 +45.80 38.50 LT SIDEWALK 2 BA 113 +29.71 38.51 LT SIDEWALK 1 57A 115 +23.90 38.50 LT SIDEWALK I 116 +94,34 38.50 LT SIDEWALK I 54A.55A 119 +17.17 38.50 LT SIDEWALK 2 n Cwt.., A as... .c 8010.4.114wu. Reserved 0 50 loo SCALE FEET 1 I -1 1/4" NMC INSTALL MARKING BALL AT ENDS CAP CONDUIT MARK FOR FUTURE USE INCLUDE TRACER WIRE I I I Scow BY BY UR T. NEMETN 110 �Pm . . LNCUCU van i� ° i: 14 n " o�ii,'."Airlrc of u1 iui DATE 1 1/4" NMC 3 -I /C.4 1 -1 /CN4 INS. GR. � W 1 JAW afam BTW 11/4" NNC 3 -1 /C.4 1 -1 /C.4 INS. GR. NOTE Sr r V) N 4 a BOLTON $ NIE. NJ K , 1 NC. CONSULTING ENGINEERS & SURVEYORS MN WNOWN SLEEPY EYE. MN . R BURNSVLLE. MN CN ,M AS.. MN RAMSEY. MN MAPLEWOOD. MN AMES, u CSAH 101 - - -- 11/4" NMC 3 -I /CW4 I -I /C.4 INS. GR. 4. SEE SPECIAL PROVISIONS FOR LIGHTING UNIT SPECIFICATIONS. 5. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO UTILIZE THE GOPHER ONE CALL EXCAVATION NOTICE SYSTEM FOR ALL UTILITY LOCATIONS. 11/4" NMC 3 -1 /C.4 1 -1 /C.4 INS. 'GR. 11/4" NMC 3 -I /C.4 1 -I /C.4 INS. GR. I. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE CONNECTION OF THE POWER FOR THE LIGHTING SYSTEM WITH SHAKOPEE PUBLIC UTILITIES. 2. THIS PLAN SPECIFIES CONDUIT SIZE, TYPE AND GENERAL LOCATIONS. THE EXACT LOCATION WILL DETERMINED IN THE FIELD. 3. ALL CONDUIT SHALL BE NMC - SCHEDULE 80 AND SHALL CARRY 1 /C.4 GREEN INSULATED GROUNDING CONDUCTOR AS SHOWN IN THE PLAN. • 1 1/4" NMC • 1 3 -1 /CW4 • 1 -1 /C •4 INS. OR. LEGEND LIGHTING UNIT TYPE SPECIAL 1 LIGHTING UNIT TYPE SPECIAL 2 INPLACE LIGHTING UNIT TYPE 3 INPLACE TUNNEL LIGHTING UNIT TYPE 4 ❑ INPLACE HANDHOLE EQUIPMENT PAD /SERVICE CABINET FURNISH AND INSTALL CONDUIT INPLACE CONDUIT SOURCE OF POWER LIGHTING PLAN AS U, O LIT OY SHEET 139 OF 162 LIGHTING STANDARDS AND BASES NO. STATION OFFSET LOCATION TYPE 8A 120+23.88 38.50 RI SIDEWALK 1 9A 122+03.88 38.50 RT SIDEWALK 1 10A 123+75.68 38.50 RT SIDEWALK I 118.128 125+55.68 38.50 RT SIDEWALK 2 138 127+39.39 38.50 RT SIDEWALK I I48 129+19.39 38.50 RT SIDEWALK I 158 130+99.39 38.50 RT SIDEWALK I 16A.17A 132+79.39 38.50 RT SIDEWALK 2 IBA 134+41.06 38.50 RT SIDEWALK 1 53A 120+97.89 38.50 LT SIDEWALK 1 52A 122+71.94 38.50 LT SIDEWALK 518 124+627538.50 LT SIDEWALK I 49A 50A 126+41.06 38.50 LT SIDEWALK 2 48A 128+16.06 38.50 LT SIDEWALK I 47A 129+91.06 38.50 LT SIDEWALK I 468 131+71.06 38.50 LT SIDEWALK I 448.45A 133+58.62 38.50 LT SIDEWALK 2 INSTALL CONDUIT CROSSING 5 BEYOND CSAH 101 ROW 4-3. NMC I-I 1/2 NMC 42" COVER MINIMUM INSTALL MARKING BALL AT ENDS CAP CONDUIT MARK FOR FUTURE USE INCLUDE TRACER WIRE CROSS AT STATION 122+12 I 1/4 NMC 3-1/C.4 I-I/C*4 INS. GR. 0 An F- (/) UJ LV HG 111151111 - 140 1.8olton Man, 2010. MIRIgnIA R aaaaaa d I 1/4" NMC 3-I/C.4 I-I/C.4 INS. GR. Cl TOO SCALE FEET - - - L_J r Scott 1 1/4 NMC 3-I /C+4 1-1/C.4 INS. GR. I I I I I I I I I I T. Itti 125 1 1/4" NMC 3-1/C.4 E=:1-1/C*4 INS. GR. 0 1E X -NA.AX X I 1/4" NBC 3-I/C.4 I-I/C.4 INS. GR. 11 I/ NB p -I/C.4 INS. JUN can. Jaw DE0.11 BTN I 1/4" NBC 3-I /C4 I-I/C4 INS. GR. & NA E NJ K. , I . CONSULTING ENGINEERS & SURVEYORS MANKATO.. FAIRMONT. MN SLEEPY EYE. MN IILLIAAR. AN BLIRMSNLLE. CHAS, MX RAMSEY. MN MAIAL EOM. YR AMES. IA I 1/4" NBC 3-I/C.4 I-I/C.4 INS. GR. I 1/4 NMC 3-I/C.4 1-1/C.4 INS. GR. C. CSAH 101 INSTALL CONDUIT CROSSING 5• BEYOND CSAH 101 ROW 4-3" NMC 1-1 1/2" NYC 42 COVER MINIMUM INSTALL MARKING BALL AT ENDS CAP CONDUIT MARK FOR FUTURE USE INCLUDE TRACER WIRE CROSS AT STATION 133+40 C.S.A.H. 101 RECONSTRUCTION LIGHTING PLAN 0 UT FAT _J HG 2 I 1/4 NMC 7 3-I/C.4 I-I/C.4 INS. GR. LEGEND LIGHTING UNIT TYPE SPECIAL 1 t Iff LIGHTING UNIT TYPE SPECIAL 2 INPLACE LIGHTING UNIT TYPE 3 c; INPLACE TUNNEL LIGHTING UNIT TYPE 4 0 INPLACE HANDHOLE EQUIPMENT PAD/SERVICE CABINET FURNISH AND INSTALL CONDUIT INPLACE CONDUIT • SOURCE OF POWER S.A.P. 70-701-07 C.T.B., C.P. 101-07 SHEET 140 162 LIGHTING STANDARDS AND BASES N0. STATION OFFSET LOCATION TYPE IRA 136 +21.06 38.50 RT SIDEWALK 1 20A 138 +09.06 38.50 RT SIDEWALK I 21A 139 +80.85 38.52 RT SIDEWALK 1 228 144+51.15 45.00 RT BEHIND SW 1 239 146 +31.15 45.00 RT BEHIND SW 1 24A 148 +11.15 45.00 RT SIDEWALK 1 43A 429 135 +31.06 137 +11.06 38.50 LT 38.50 LT SIDEWALK SIDEWALK I 1 4IA 138 +91.06 38.50 LT BOULEVARD I 40A 140 +72.70 47.84 LT BOULEVARD I 39A 143 +60.19 47.34 LT BOULEVARD I 388 145 +41.15 43.00 LT BOULEVARD 1 378 147 +21.15 43.00 LT BOULEVARD 1 36A 148 +93.87 43.00 LT BOULEVARD I O LG1 M 1 I I I I I 4 - - 1 1/4" NMC 3 -1 /C•4 I 1 -1 /C •4 INS. OR. I I I I I I 1 1 I I 1 1/4" r4MC 3 -1/C•4 1- 1 /C•1 INS. GR. T -�-- 1 T 1 r I . 1 Ct� B MARSCHALL ROAD I I 11/4" NMC 3 -1/C•4 I -I /C•4 INS. GR. ll I / l II 1I 11 c _ J 1 1 INS. GR. 'J SBI MARSCIi / AL / L ROAD I 1 i 1 I I 1 1 L [ - -- Ct NB MARSCHALL ROAD INPLACE: 11/4" NMC EXTEND: INPLACE CONDUIT INTO AND OUT OF LIGHT BASES F&I: 3-I/C*4 1 -1 /C*4 INS. GR. CSAH 101 / INPLACE: I 1/4" NMC EXTEND: INPLACE CONDUIT INTO AND OUT OF LIGHT BASES / F&I: 3 -1/C•4 1 -1 /C•4 INS. GR. I NB MARSCHALL ROAD INPLACE: I 1/4" NMC EXTEND: INPLACE CONDUIT INTO AND OUT OF LIGHT BASES F&1: 3-1/C•4 I -1/C•4 INS. GR. O to 01 INPLACE: 1 1/4" NMC EXTEND: INPLACE CONDUIT INTO AND OUT OF LIGHT BASES FM: 3 -1 /C•4 1 -I /C•4 INS. GR. LEGEND -I- LIGHTING UNIT TYPE SPECIAL 1 LIGHTING UNIT TYPE SPECIAL 2 INPLACE LIGHTING UNIT TYPE 3 INPLACE TUNNEL LIGHTING UNIT TYPE 4 0 INPLACE HANDHOLE NM EQUIPMENT PAD /SERVILE CABINET FURNISH AND INSTALL CONDUIT INPLACE CONDUIT SOURCE OF POWER eo„o-.. M.,,H. I++ MO..:Rw.,. R......M 0 50 100 SCALE ,),fiott 7 7BI P SPECIE NATATICK OR HE 's PREr M PxaR ESSIauM. ENGINEER LONER NW utls OF THE iTAiwoi u:�,tic � • BRYAN 7. tic xn N4”. WAN JBW JBW mum ETA Ai \ BOLTON $ MB N K. , INC. CONSULTING ENGINEERS & SURVEYORS NNATO. LM FARMONi MN SLEEPY EYE.. E tl BURNSVILLE. MN HAW.. RAMSEY, MY LEWNp LA MN AMES, IA S.A.P. 70- 701 -07 C.T.B., C.P. 101 -07 C.S.A.H. 101 RECONSTRUCTION LIGHTING PLAN :NEE* 141 162 LIGHTING STANDARDS AND BASES NO. STATION OFFSET LIGATION TYPE 25A 150.01.63 45.00 RT BEHIND SW I 26A 151.51.15 45.00 RT BEHIND SW 1 27A INPLACE BRIDGE 3 2BA INPLACE BRIOGE 3 29A INPLACE BRIDGE 3 35A 150.61.15 43.00 LT BCULEVARD I 34A 152.32.7 LT BCULEVARD I 33A INPLACE BRIDGE 3 32A INPLACE BRIDGE 3 31A INPLACE BRIDGE 3 30A INPLACE TUNNEL UNIT BRIDGE 4 150 CON... A 11M4. I,t xi4. A MHN. R......N X INPLACE. 1 1/4" NBC EXTEND INPLACE CONDUIT INTO AND OUT OF LIGHT BASES F61. 3 -I /C•4 1 -1 /C•4 INS. GR. INPLACE. 1 1/4" NBC EXTEND. INPLACE CONDUIT INTO AND OUT OF LIGHT BASES F61. 3-I/C.4 1 -I /C•4 INS. GR. 0 50 100 SCALE INPLACE. 1 1/4" NBC EXTEND, INPLACE CONDUIT INTO AND OUT OF LIGHT BASES F61. 3 -1 /C•4 I -I /C•4 INS. GR. INPLACE. 11/2" NBC 3 -1/C•4 1 -1/C•4 INS. GR. INPLACE 11/2" NBC 3 -I /C•4 1 -1 /04 INS. GR. SPLICE INPLACE CABLES WITH FURNISHED CABLES IN HH 2 AND HH 3 • 155 - srccrcla7loN aR REPOR. .. e�.z a woin w. "o.rc <i'v"eE�"wnsw• .w ..0 . I.N u�Nw ns. xx xx xxxx . CSAH 101 wow° A JBw Dune JBw BIN HH 2 BOLTON $ MBIV K. 11 C. CONSULTING ENGINEERS & SURVEYORS MN Mx SL EEPY BYE. R . MN BURNSVILLE. MNCHASKA. MN RAMSEY. uN PLEV000 LMN AMES.A B AND R DENOTE CURRENT CARRYING CONDUCTORS W DENOTES NEUTRAL CONDUCTOR HH HH LEGEND .�j LIGHTING UNIT TYPE SPECIAL 1 Ty LIGHTING UNIT TYPE SPECIAL 2 ▪ INPLACE LIGHTING UNIT TYPE 3 INPPLACCE TUNNEL LIGHTING UNIT O INPLACE HANDHOLE FPA PAD MOUNTED SERVICE CABINET (TYPE L11 240/480 VOLT METERED 4 CIRCUIT BREAKERS EQUIPMENT PAD /SERVICE CABINET FURNISH AND INSTALL CONDUIT INPLACE CONDUIT • SOURCE OF POWER S.A.P. 70- 701 -07 C.T.B., C.P. 101 -07 C.S.A.H. 101 RECONSTRUCTION LIGHTING PLAN M 142 162 num.... • 21)111 1■1111Mt. 25 50 ITQT■TI SCALE FEET Xou ii:ElEtE.,;:6HEEKiEFE UTE CAMEO I NJ. CONSULTING ENGINEERS & SURVEYORS MANRATO. FAMMON7,11,N SLEEPY EYE, MN MLLVAR, MN BURNSVILLE. MN [BASRA. MN RAMSEY, MN MAPLEAMB, IN AMES, IA .01 DF NIGHTTIME FRIENDLY Consistent with LEED' goals & Green Globes'criteria for light pollution reduction LuxMaster Luminaire Series 153 Area Lighting 200 -400W HPS, 200 -400W MH P R O D U C T O V E R V I E W Applications: Parking lots Roadways Residential communities Commercial environments Office communities DIMENSIONS Features: Die -cast aluminum housing for long -life performance Optical assembly designed for maximum performance Ballast tray electrical system for installation and maintenance ease "Breathing Seal" developed by American Electric preventing contaminants from entering optical assembly Optics available in flat tempered glass, sag glass, drop acrylic and drop poly - carbonate Available in a variety of IES light distributions patterns Standard product is designed to mount to pipe mast arm. Direct pole mount arms are available UL Listed All electrical components warranted by American Electric Lighting's 6 -year guarantee Mogul base E39 socket, standard Suitable for -30 °C MH / -40 °C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15 PREFERRED SELECTION CATALOG NUMBERS I AA IANIM AA a MT. MIN AM AA R Ro O � ORDERING NUMBER LOGIC WITH CUTOFF OPTICS APPLICATIONS • For roadway, highway or parking lot applications where light trespass could be a problem SPECIFICATION FEATURES • Universal two -bolt slipfitter • Die -cast aluminum housing with polyester powder gray paint finish • Adjustable mogul base socket (house side) - E39 standard • Standardized reflector • "Dead back" tunnel type, FRP terminal board • e/ co listed for wet location available as an option MSCL PRODUCT IDENT 40 WAT TAG E S LIGHT SOURCE 1 VOLTAGE A BALLAST TYPE 2 PE FUNCTION 1 IGNITOR MOUNTING F LENS TYPE MC3 IES DISTRIBUTION TYPE F OPTIONS XXXX MSCA = M -400 with 4 -Bolt Slipfitter MSCL M -400 with Cutoff * Optics 2 -Bolt Slipfitter _ Previously IESNA Full Cutoff Optics XX 07 = 70 10 =100 15 =150 155V) 17 =175 20 =200 24 = 250/400 25 =250 32 = 320 35 = 350 40 =400 84 =85 (4000K) 83 =85 (3000K) NOTE: Dual wattage connected for lower wattage X E = Energy Act Compliant Pulse MH (EPMH) S = HPS Standard: HID lamp not included. Q= QL Induction T = Induction Induction: Supplied with lamp. X 60Hz 0 = 120/208/ 240/277 Multivolt 1 =120 2 = 208 3 = 240 4 = 277 5 = 480 7 = 120X240 8 = 240V Ballast 120V PE Receptacle not reconnect - able D = 347 G = 200 -277 T = 220 W= 230 50Hz 6 = 220 X See Ballast Selection Table A = Autoreg E = Induction Ballast G = Mag -Reg with Grounded Socket Shell H = HPF Reactor or Lag M = Mag -Reg N = NPF Reactor or Lag P = CWI with Grounded Socket Shell X 1= None 2 =PE Receptacle NOTE: Receptacle connected same voltage as unit except as noted. Order PE Control separately. X 1= Non Plug -in None 2 = Plug -in base and Ignitor X F = Flat Glass * G = Shallow Glass Globe L = Polycar- bonate Clear Globe (250 watt Maximum) HPS only * = Previously IESNA Full Cutoff Optics • Metal pest guard standard (not required for 2 in. pipe mounting) • No -tool PE receptacle • Plug -in ignitor available • Cutoff photometrics • External paddle type stainless steel bail latch • True 90° cutoff —no light above 90° (meets RP8 -2000 for full cutoff) with flat glass XXX See Photometric Selection Table M = Medium C = Cutoff * 2 = Type I I 3 = Type llI 4 = Type IV * = Previously IESNA Full Cutoff Optics XXX C = Charcoal filter F = Fusing (Not available with multivolt or dual voltage) J = Line Surge Protector, Expulsion Type U = u) / listed with glass only (60Hz only)