HomeMy WebLinkAbout15.B.3. Smoke Detectors in Residential Occupancies-Ord. No. 666 CONSENT CITY OF SHAKOPEE IS. 13. 3.. Memorandum TO: Mayor and City Council Mark McNeill, City Administrator FROM: Tom Pitsch neider, Fire Inspectorr SUBJECT: Revision to Section 4.50 of the Shakopee City Code, amending the city code requirements for fire warning systems. MEETING DATE: May 20,2003 INTRODUCTION: The 2003 State Fire Code has additional requirements for the placement and operation of smoke detectors in residential occupancies. These additional requirements are not included in the current Section 4.50 making the local ordinance less restrictive than the State Fire Code. The revisions to Section 4.50 make this ordinance equal to the State Fire Code requirements and clarifies where and how smoke detectors are installed in residential occupancies within the City of Shakopee. ALTERNATIVES: 1. Offer and pass Ordinance No. 666, AN ORDINANCE AMENDING SECTION 4.50 OF THE CITY CODE REQUIRING FIRE WARNING SYSTEMS, as presented. 2. Offer and pass Ordinance No. 666, AN ORDINANCE AMENDING SECTION 4.50 OF THE CITY CODE REQUIRING FIRE WARNING SYSTEMS, with revisions. 3. Do not authorize Ordinance No. 666. ACTIONS REQUESTED: Offer and pass Ordinance No. 666, AN ORDINANCE AMENDING SECTION 4.50 OF THE CITY CODE REQUIRING FIRE WARNING SYSTEMS, as presented. ORDINANCE NO. 666, FOURTH SERIES AN ORDINANCE AMENDING SECTION 4.50 OF THE CITY CODE REQUIRING FIRE WARNING SYSTEMS. THE CITY COUNCIL OF THE CITY OF SHAKOPEE, MINNESOTA, ORDAINS: Section 1. Section 4.50 of the +he City Code Subdivision Section 1.50 is amended to read: SEe. 4.50. FIRE WARNING SYSTEMS IN RESIDENTIAL OCCUPANCIES. Subd. 1. Fire Warnin2 Systems Required. Every hotel, ef motel and dwelling unit, every sleeping room and every dVlelling unit, including single dwellings, mobile homes and every rooming house shall be provided with ilE: approved smoke detector~ as hereinafter set out. Subd. 2. Tvpe of Wamin!! Device. W aming device~ required by this Section shall be one that is activated by smoke and shall conform to UBC Standard 43 6 the requirements of the Minnesota State Building Code and the Minnesota State Fire Code and any subsequent revisions. Subd. 3. Where Installed Installation ReQuirements. A. All units shall be installed at a point centrally located in the corridor or an area giving access to rooms used for sleeping purposes and v/here the sleeping rooms are located on an upper level the required detector or v:arning device shall be placed at the center of the ceiling directly above the stainvay. Detectors shall be installed in sleeping areas and rooms. B. All detectors shall be located installed on the ceiling and shall be mounted not less than six (6) inches from a wall. Under peculiar circumstances When detectors cannot be installed on the ceiling they may be located installed on a wall and shall be mounted but must be at least twelve (12) inches ffem down from the ceiling. C. Those installed in single family dVlellings and mobile homes may be activated by self contained battery. Those located in hotels, motels or multiple dwelling units shall be permanently '",ired to insure that the installation '.vill not interfere with the operating characteristics of the detector, and in any e'lent the signals of any alarm prescribed for by this Section shall be sufficiently audible in all sleeping rooms to '.vaken sleeping occupants. Detectors shall be installed in every room in the path of the means of egress from the sleeping area to the door leading from the guestroom or suite. D. Detectors shall be installed in each story within the guestroom, dwelling unit or suite, including basements. For guestrooms, dwelling units or suites with split-levels and without an intervening door between the adi acent levels, a smoke alarm installed on the upper level shall suffice for the adiacent lower level provided that the lower level is less than one full story below the upper level Subd. 4. Faree and Effect Power Source and Interconnection. This Section and all installations required thereby shall be in full force and effect from and after the 1st day of January, 1979. Power source and interconnection shall be in accordance with the Minnesota State Building Code and the Minnesota State Fire Code and any subsequent revisions. Subd. 5. Inspection and Failure to Comply. All premises required to be provided with fire warning systems as required by this code equipped '.vith alann by this Section or 'Naming device shall be open to inspection by duly designated officers ofthe City at any and all reasonable times, Subd.6. Failure to Comply. It is unlawful for any person to fail to comply with the provisions of this Section and fail to keep the warning devices above described fully operational at all times. Each day of failure to comply with this Section constitutes a separate offense. The provisions of this Subdivision are not intended to be an exclusive remedy. The City may, at its option, proceed in a civil action to restrain the continued occupancy of any hotel, motel, dwelling unit. rooming house or other structure in which sleeping rooms are occupied by tenants, until the provisions of this Section are fully complied with. Section 2. Effective Date. This ordinance becomes effective from and after its passage and publication. Adopted in session of the City Council of the City of Shakopee, Minnesota, held this day of ,2003. Mayor of the City of Shako pee ATTEST: City Clerk